Sternotomy

  • Skin incision is commonly made in the midline from jugular notch to xyphoid. 
    • NOTE: more advanced surgeons may choose to reduce the size of the incision, particularly at the top.
  • Cell-saver suction is utilized to retrieve any blood loss during the procedure.
  • Generally, at the sternal notch staying on the bone with the bovie cauterization and then using blunt dissection with a finger to palpate behind the upper manubrium to confirm that the space is clear. Similar blunt dissection at the xyphoid.
  • A sternal saw is used to open the entire length of the sternum from sternal notch to xyphoid process, staying in the midline of the sternum.
  • Bleeding from the sternal marrow and periosteum is commonly controlled to avoid ongoing oozing throughout the procedure. A topical absorbable hemostat such as SURGICEL™ FIBRILLAR Absorbable Hemostat can be applied to the sternal edges and bolstered with a sterile drape and the retractors.
     

Cannulation

  • The pericardium is opened from the diaphragm to its reflection at the upper ascending aorta, and the heart is exposed.
    • NOTE: The upper pericardium is frequently covered in fatty tissue and remnants of the thymus gland.  This can be a source of ongoing bleeding.
  • Usually, 2-0 silk pericardial sutures are placed to retract the pericardium and expose the heart and great vessels.
     
  • Arterial Cannula is placed.
  • Venous Cannula is placed.
  • Retrograde Cardioplegia Cannula may be placed as needed.
    • NOTE: Retrograde Cardioplegia cannula is usually placed in more complex procedures or when have aortic Insufficiency.
       

Arresting the Heart

  • An aortic cross clamp is applied across the aorta between the aortic cannula and the aortic root needle cutting off the flow of blood from the aortic cannula to the heart. 
     

Insertion of Superior pulmonary Vein vent

Accessing The Aortic Valve

  • An aortotomy is made just above the sinotubular junction. 
  • Sutures are frequently placed to in the aortic wall to expose the valve.
  • The valve is inspected, and the coronary ostia are observed.
  • The aortic valve is excised. 
    • NOTE: Increasing use of aortic valve repair techniques provide options for valve repair in selected cases of patients with aortic insufficiency.
  • The annulus is debrided of any additional calcification. Care is taken to avoid fragments of calcium for falling into the ventricle. 
  • Valve sizers are then used to select the appropriately sized valve.
    • NOTE: it is important to select the largest valve possible. Placing too small of a valve for a given patient’s BMI can result in Patient – Prosthesis Mismatch (PPM).
  • 12 to 18 Valve sutures (pledgeted 2-0 Ethibond Excel) are then placed around the circumference of the aortic valve annulus.  Pledgets are usually placed on the ventricular side of the annulus. 
  • A suture guide is frequently used to organize the sutures.
  • The valve sutures are then placed through the prosthetic valve and annulus.
  • The prosthetic valve is lowered down onto the annulus. It is important to confirm that the valve is well seated on the native annulus.
  • Valve sutures are tied down circumferentially. 
  • The prosthetic valve is inspected and both coronary ostia are observed. 
  • The aortotomy is closed with a continuous running non-absorbable suture (Usually in two layers).
  • The cross clamp is removed.

     

Preparing to disconnect from CPB

  • Once the cross clamp is removed blood flow to the coronary arteries is restored and spontaneous heart rhythm usually returns.  
  • Temporary pacing wires and chest tubes are placed.
  • If the heart does not spontaneously start the temporary pacing wires may be used.
    • NOTE: It is important to visualize both lungs expanding while anesthesiologist begins ventilating the patient.

 

Discontinuing cardiopulmonary bypass and cannulation 

  • Once there is an adequate rhythm with reasonable contraction of both ventricles and the both lungs are being ventilated, the patient is ready to be weaned from the heart-lung machine.
  • When CPB has been discontinued, the venous cannula, retrograde cannula and aortic root needle is removed. 
  • During this time any blood volume remaining in the heart-lung machine is returned to the patient.
  • The aortic cannula is removed.
     
  • Confirm that there are no areas of active bleeding. Consider placing topical absorbable hemostat such as SURGICEL™ FIBRILLAR Absorbable Hemostat - on the sternal edges prior to closing the sternum to minimize oozing from the lower sternal table and to utilize its bactericidal affects. 
  • Proximal anastomoses and cannulation sites are inspected for bleeding / oozing.
  • Integrity of the bypass grafts is checked for twists or kinks. 
  • The overall heart function is assessed.
  • The sternotomy retractor is removed.
  • A laparotomy pad is placed in the incision and chest wall is inspected for bleeding.
  • Sternal wires are placed starting from the top (manubrium), using Surgical stainless-steel suture.
  • The wounds are closed using synthetic absorbable monofilament, such as Monocryl™ Plus Antibacterial suture, or a knotless tissue control device, such as STRATAFIX™ Knotless Tissue Control Devices, and a topical skin adhesive such as DERMABOND PRINEO™ Skin Closure System or any appropriate dressing.