Intended for healthcare professionals

HARMONIC™ 1100 Shears

When operating in tight spaces or near vital structures, precision is essential. HARMONIC™ stands unrivaled as the undisputed ultrasonic leader and proven to deliver minimal thermal impact on tissue1,2A with precise energy delivery.3,4 HARMONIC™ 1100 Shears, our most advanced ultrasonic device, delivers secure vessel sealing up to and including 7mm5-7, faster transection speeds, lower maximum blade temperatures, and more precise tissue dissection.8-12B

About this device

HARMONIC™ 1100 Shears is a sterile, single-patient-use advanced ultrasonic energy device intended for general dissection, vessel sealing, back-scoring, otomy creation, mesentery marching, or meticulous tissue plane dissection. It features an ergonomic handle, integrated handpiece, and Advanced Hemostasis technology with dual energy-delivery buttons enabling focused dissection or coagulation. Two shaft lengths (20cm and 36cm) provide adaptability across a range of procedures.

Specialties

General, Pediatric, Gynecologic, Urologic, Thoracic

Procedures

Electrosurgery, sealing and transection of lymphatic vessels, and other open and endoscopic procedures

Economic evidence

A recent peer-reviewed publication showed that using HARMONIC™ ultrasonic devices may result in the following reduced annual economic outcomes compared to other advanced energy devices13C:

  • OR time costs by over $600K
  • Hospital stay costs by over $125K

Clinical and surgical benefits

A meta-analysis comparing the HARMONIC™ scalpel to conventional techniques in gastrectomy for dissection and coagulation found the HARMONIC™ scalpel demonstrated significant reduction in14D:

  • Operating time
  • Intraoperative blood loss

Features & benefits

HARMONIC™ 1100 Shears

Precision

Curved, tapered tip that enables more precise dissection than HARMONIC ACE™+7 Shears.10,12,15E Its unique shape mimics a mechanical dissector and may reduce the need to use a separate dedicated dissecting instrument.10,12,16-18F

Speed

Speed

Reduce heat exposure on tissue with transection speeds 35% faster when using the Energy button8-10G and 40% faster when transecting vessels 5-7mm in diameter using Advanced Hemostasis mode.7,10,11,19,20H

heat control

Heat control

Achieve greater control with lower maximum blade temperature.11I HARMONIC™ 1100 Shears has an improved Adaptive Tissue Technology algorithm that actively controls blade heat11J, which may protect surrounding tissue and vital structures.

Learn how to use this device

HARMONIC™ 1100 Shears

View playlist

Supporting documentation

PDF

HARMONIC™ Portfolio VAC pack

PDF

HARMONIC™ portfolio overview

PDF

HARMONIC™ portfolio brochure

PDF

Adaptive tissue technology overview

PDF

HARMONIC™ 1100 Shears ODP
Select all (5)

Related products

HARMONIC™ 700 Shears with Advanced Hemostasis

HARMONIC™ 700 Shears with Advanced Hemostasis

HARMONIC™ devices are a leader in Advanced Energy devices and the undisputed ultrasonic leader proven to minimize the impact on tissue with precise energy delivery.1,2A  When operating in tight spaces or near critical structures, precise energy delivery becomes vital.


The HARMONIC™ 700 Shears elevate this legacy. Offering the same precision, versatility, and sealing confidence as the HARMONIC ACE™+7 Shears, while integrating improved Adaptive Tissue Technology and advanced temperature management for even better tissue protection3-7B for vessels up to and including 7mm in diameter.3C

harmonic focus plus shears

HARMONIC FOCUS™+ Shears

When operating in tight spaces or near critical structures, precise energy delivery becomes vital. The HARMONIC FOCUS™+ is an ultrasonic advanced energy device that enables exceptionally precise energy delivery and dissection with strong sealing1-3A in open procedures with it curved, fine tip and slim profile.4

HARMONIC FOCUS™+ Long Shears

Operating in tight spaces or near critical structures demands precise energy delivery. The HARMONIC FOCUS™+ Long Shears is an ultrasonic advanced energy device that enables exceptionally precise energy delivery and dissection with strong sealing1-3A in open procedures with its curved, fine tip, slim profile4, and added length that allows access in deep anatomy.5B

References

A. Per internal market share data and preclinical testing of thermal impact.

B. Compared to HARMONIC ACE™+7 Shears

C. Budget Impact Model analysis comparing portfolio-wide adoption of Ethicon energy devices versus other non-Ethicon manufactured energy devices in a typical hospital performing 8,000 annual electrosurgery procedures across five specialties (bariatric, colorectal, thoracic, gynecology, and general surgery).

D. In a meta-analysis comparing HARMONIC™ devices to conventional techniques (p<0.00001). 

E. Based on a preclinical evaluation

F. Based on a preclinical study

G. Based on bench top study with porcine vessels 3-5 mm in diameter with HARMONIC™ 1100 at power level 5 and HARMONIC ACE™+7 at power level 3 (p<0.001).

H. In a bench top study comparing sealing times of HARMONIC ACE™+7 and HARMONIC™ HD 1000i, HARMONIC™ HD 1000i Shears transected vessels faster than HARMONIC ACE™+7 (mean vessel transection time of 9.186 seconds vs 15.291 seconds). The algorithm for Advanced Hemostasis on HARMONIC™ HD 1000i and HARMONIC™ 1100 Shears are the same.

I. Based on benchtop study that showed HARMONIC™ 1100 had significantly lower maximum blade temperature than HARMONIC™ HD 1000i Shears after 15 tip bite transections.

J. Compared to previous generations of HARMONIC™ devices

  1. Ethicon, Market Share Monthly Insights Energy. April 2022 YTD
  2. Ethicon, HARMONIC™ Adaptive Tissue Technology Memo. 03/18/2021. Windchill Document #500660262 
  3. Ethicon, Project Gemini: Claim Rationale. 07/19/2022. Windchill Document #501001842
  4. Ethicon, HARMONIC™ 700 Claims Rationale Design History File Memo for Project Gemini. 05/16/2022. Windchill Document #500951334
  5. Ethicon, HARMONIC™ 1100 Shears Instructions for Use   
  6. Ethicon, HARMONIC™ HD 1000i Shears Instructions for Use   
  7. Ethicon, Buccaneer Harmonic Burst Pressure Investigation. 05/07/2020. Windchill Document #PRC092654     
  8. Ethicon, Buccaneer Energy Button Vessel Claims. 04/07/2016. Windchill Document #PRC074432   
  9. Ethicon, Scarlet DV- Vessel Transection Speed (and Burst Pressure). 11/02/2020. Windchill Document #PRC094080   
  10. Ethicon, Scarlet Witch Physical Equivalence Memo. 04/13/2020. Windchill Document #SCN075090
  11.    Ethicon, Project Scarlet: Claims Jaw and Distal Shaft Temperature. 04/20/2021. Windchill Document #PRC095370   
  12. Ethicon, HARMONIC™ HD 1000i Open Shears (HARHD20) and HARMONIC™ HD 1000i Laparoscopic Shears (HARHD36): Design Verification Acute Study in the Pig. 10/26/2016. Windchill Document #PSP004888
  13.  Ferko N, Wright G, Syed I, Naoumtchik E, Tommaselli G, Gangoli G. A Device Category Economic Model of Electrosurgery Technologies Across Procedure Types: A U.S. Hospital Budget Impact Analysis. Journal of Medical Economics. 2021;24:524-535
  14. Cheng H, Hsiao C-W, Clymer J, et al. Gastrectomy and D2 Lymphadenectomy for Gastric Cancer: A Meta-Analysis Comparing the Harmonic Scalpel to Conventional Techniques. Int J Surg Oncology. 2015;397260:1-11
  15. Welling A, Scoggins P, Cummings J, Clymer J, Amaral J. Superior dissecting capability of a new ultrasonic device improves efficiency and reduces adhesion formation. Global Surgery. 2017;3(1):1-5
  16. Ethicon, Buccaneer Validation Marketing Questions. 05/16/2016. Windchill Document #DOC021988
  17. Ethicon, HARMONIC™ HD 1000i Competitive Overlays. 03/18/2016. Internal Document
  18. Ethicon, Project Scarlet Design Validation Completion Report. 02/05/2021. Windchill Document #PRC094018
  19. Ethicon, Buccaneer DV- Vessel Transection Speed. 05/24/2016. Windchill Document #PRC074125
  20. Ethicon, Vic - transection time evaluation with surgeons. 06/01/2011. Windchill Document #PRC051292


For complete indications, contraindications, warnings, precautions, and adverse reactions, please reference full package insert.

The third-party trademarks used herein are trademarks of their respective owners. 

US_SRG_ENER_124178.1