Device Specifications and Comparisons

MEGADYNE Disposable Patient Return Electrodes is a single use patient return electrode designed to be used wherever monopolar electrosurgery is indicated. The intended use of this device is to conduct monopolar electrosurgical energy from the target tissue of a patient back to one or two electrosurgical units (ESU), or generators. It is available with either pre-attached cords or reusable cords.

Select Competitive Products: Valleylab PolyHesive Corded Patient Return Electrodes, 3M  Universal Electrosurgical Pads

Featured Product

MEGADYNE™ Disposable Patient Return Electrodes MEGADYNE MEGA SOFT Patient Return Electrodes

MEGADYNE Disposable Patient Return Electrodes

MEGADYNE MEGA SOFT Universal Plus Reusable Patient Return Electrode

Codes

0855C, 0855CL, 0865C
0845M2K01, 0845M2K02, 0845M2K03, 0845M2K04, 0845M2K05, 0845M2K06, 0845M2K08, 0845M2K09, 0846M2K01, 0846M2K02, 0846M2K03, 0846M2K04, 0846M2K05, 0846M2K06, 0846M2K08, 0846M2K09, 0848M2K01, 0848M2K02, 0848M2K03, 0848M2K04, 0848M2K05, 0848M2K06, 0848M2K08, 0848M2K09, 0847M2K01, 0847M2K02, 0847M2K03, 0847M2K04, 0847M2K05, 0847M2K06, 0847M2K08, 0847M2K09

Compatible With

  • MEGEN1
  • MEGEN1

Accessories Included

  • M2K01: Standard Connect Cable, 8ft
  • M2K01: Standard Connect Cable, 14.4ft
  • M2K03: Phone Plug Connect Cable, same as B-205 adaptror, 8ft
  • M2K04: Phone Plug Connect Cable, same as B-205 adaptror, 14.4ft
  • M2K05: Extended Phone Plug Connect Cable, same as B-210 adaptror, 14.4ft
  • M2K06: Argon Beam Connector Cable, same as A-238 adaptror, 8ft
  • M2K07: Replacement Pigtail Cable, 2ft
  • M2K08: Compatibility Cable, 8ft
  • M2K09: Compatibility Cable, 14.4ft
  • PKIT001: MEGA SOFT repair kit

Cord Length

  • Pediatric Dual Plate Return Electrode (0865C): 9ft, 2.7m
  • Dual Plate Return Electrode (0855C): 10ft, 3.0m
  • Dual Plate Return Electrode (0855CL): 15ft, 4.6m
  • 8’ (M2K01, M2K03, M2K06, M2K08)
  • 14.4’ (M2K02, M2K04, M2K05, M2K09)

Description

  • Traditional dual plate disposable patient return electrodes with pre-attached cords available in a variety of sizes for pediatric and adult patients.

24-month Reusable Patient Return Electrode available in single or dual cord configurations. 

Weight Range

  • Pediatric Dual Plate Return Electrode (0865C): 6-33lbs, 2.7-15kgs
  • Dual Plate Return Electrode (0855C & 0855CL): >33lbs, >15kgs

MEGA SOFT Reusable Patient Return Electrodes are indicated for patients 12 years of age and older, with no maximum weight restriction. 

Pad Size ( L x W)

  • MEGA SOFT Universal (0845) & Universal Dual (0846) Reusable Patient Return Electrode:  36" X 20"             
  • MEGA SOFT Universal Plus (0847) & Universal Plus Dual (0848) Reusable Patient Return Electrode:  36" X 20" 

Pad Thickness

  • MEGA SOFT Universal (0845) & Universal Dual (0846) Reusable Patient Return Electrode:  1/8"                       
  • MEGA SOFT Universal Plus (0847) & Universal Plus Dual (0848) Reusable Patient Return Electrode:  1/4"

Pad Weight

  • MEGA SOFT Universal (0845) & Universal Dual (0846) Reusable Patient Return Electrode: 4lbs, 1.8kgs       
  • MEGA SOFT Universal Plus (0847) & Universal Plus Dual (0848) Reusable Patient Return Electrode:  8lbs, 3.6kgs

Pad Use

  • Single-Use, Disposable
  • Reusable

Patient Indication

  • Pediatric Dual Plate Return Electrode (0865C): 6-33lbs, 2.7-15kgs
  • Dual Plate Return Electrode (0855C & 0855CL): >33lbs, >15kgs     
  • 12 years of age and older

Max Life

  • 24 months

Modality

  • Monopolar
  • Monopolar

Surgical Approach

  • Open & Laparoscopic
  • Open & Laparoscopic

Qty./Box

  • 50
  • 1 electrode + 1 or 2 cables (single vs. dual plug)

Supporting Documentation