You are about to leave jnjmedtech.com. By clicking to continue, you will be taken to a web site governed by their own Legal and Privacy Policies.
Features & Benefits
Uniform Cooling at Half the Flow Rate
Compared to SMART-AF study:
- Procedure time reduced 19%1
- Fluoroscopy time reduced 55%1
Improves Outcomes with More Stable Catheter-Tissue Contact Force
- Allows active measurement of stable contact force and catheter tip direction
- Provides consistent movement in response to contact force using precision spring
- Sends accurate location reference signal via location sensor and transmitter coil
- Promotes consistent lesion formation
- Reduces ablation time2
- Improves outcomes with more stable catheter-tissue contact force3
Product Resources
THERMOCOOL SMARTTOUCH® SF Catheter
Ordering |
Description |
Outer |
Curve |
Tip |
Spacing |
Insertion |
D134801 |
Bi-Directional with Curve Visualisation |
8F |
DD |
3.5mm |
1-6-2 mm |
115mm |
D134802 |
Bi-Directional with Curve Visualisation |
8F |
FF |
3.5mm |
1-6-2 mm |
115mm |
D134803 |
Bi-Directional with Curve Visualisation |
8F |
JJ |
3.5mm |
1-6-2 mm |
115mm |
D134804 |
Bi-Directional with Curve Visualisation |
8F |
FJ |
3.5mm |
1-6-2 mm |
115mm |
D134805 |
Bi-Directional with Curve Visualisation |
8F |
DF |
3.5mm |
1-6-2 mm |
115mm |
D134701 |
Uni-Directional with Curve Visualisation |
8F |
D |
3.5mm |
1-6-2 mm |
115mm |
D134702 |
Uni-Directional with Curve Visualisation |
8F |
F |
3.5mm |
1-6-2 mm |
115mm |
D134703 |
Uni-Directional with Curve Visualisation |
8F |
J |
3.5mm |
1-6-2 mm |
115mm |
Associated Cables
Catalog |
Connects |
CR3434CT |
Catheter to CARTO® 3 System PIU |
Associated Tubing
Catalog |
Description |
CFT001 |
CoolFlow® Pump Tubing (1 per pack) |
SAT001 |
SMARTABLATE® System |
References
1Prospective safety assessment of the THERMOCOOL SMARTTOUCH® SF family of contact force sensing catheters for the treatment of drug refractory symptomatic PAF(SMART-SF). Biosense Webster, Inc. Final Clinical Report, January 2016
2Martinek M, Lemes C, et al. Clinical impact of an open-irrigated radiofrequency catheter with direct force measurement on atrial fibrillation ablation. Pacing Clin Electrophysiol. 2013;35(11):1312-1318
3Kumar S, Morton JB, Lee J, et al. Prospective characterization of catheter-tissue contact force at different anatomic sites during antral pulmonary vein isolation. Circ Arrhythm Electrophysiol. 2012;5:1124-1129.
Disclosures
The THERMOCOOL SMARTTOUCH® SF Catheter is indicated for the treatment of drug refractory recurrent symptomatic paroxysmal atrial fibrillation (AF) and for drug refractory recurrent symptomatic persistent AF (continuous AF > 7 days but < 1 year), refractory or intolerant to at least 1 Class I or III AAD, when used with the CARTO® 3 System.
105369-201014
Last Updated on 6/29/2020
This site is published by Biosense Webster, Inc. which is solely responsible for its contents. It is intended for visitors from the United States.