TRUFILL™ n-BCA Liquid Embolic System

Now available as PROCEDURAL SET

About this device

TRUFILL™ Differentiators

Every AVM is unique, the TRUFILL™ n-BCA Liquid Embolic System provides you with the flexibility needed to create a customized SOLUTION for each patient.

Each procedure presents with different challenges and only you know what SOLUTION is right for your patient. The TRUFILL™ n-BCA Liquid Embolic System empowers you to:

  • Adjust polymerization times to the hemodynamic flow rate and distal embolization desired
  • Customize the amount of TRUFILL™ Tantalum in the SOLUTION to meet your visualization need

Good Safety Profile​

Complication rates associated with TRUFILL™ n-BCA Liquid Embolic System are numerically lower than those with Onyx LES but not statistically significant (an RCT and 2 retrospective studies reported similar overall complication rates in the cohort of patients treated with TRUFILL™ n-BCA Liquid Embolic System compared to Onyx LES cohort.)

Lower Total Procedural Costs​

TRUFILL™ n-BCA Liquid Embolic System does not require the use of expensive detachable tip microcatheters or dual lumen balloon catheters.3

Clinical evidence

Studies have demonstrated that TRUFILL™ n-BCA Liquid Embolic System has:

1.6%

Low Catheter Retention Rate

In a randomized control trial, the catheter retention rate of TRUFILL™ n-BCA Liquid Embolic System of 1.6% (1/63) was lower than 9.3% (5/54) for Onyx LES.1

~37 min

Significantly Shorter Fluoroscopy Time

The mean fluoroscopy time of 37±21 minutes with TRUFILL™ n-BCA Liquid Embolic System, significantly shorter than 57±26 minutes observed with ONYX™ LES (p <0.0001).2

~2.1 hrs

Significantly Shorter Procedural Time

A 2008 retrospective study reported a mean procedure time with the TRUFILL™ n-BCA Liquid Embolic System of 2.1±0.9 hours was reported to be significantly shorter than with ONYX™ LES of 2.6±0.8 hours (p=0.001).2

System attachments & accessories

TRUFILL™ n-BCA Liquid Embolic System

Procedural Set Components

Accessories included to prepare TRUFILL™ n-BCA Liquid Embolic System in a single sterile set.

Related products

Prowler® EX Microcatheter

Prowler® EX Microcatheter

The PROWLER® EX Microcatheter is a variable stiffness, single lumen catheter designed to access small, tortuous vasculature. The catheter has a hydrophilic coating to provide lubricity for navigation of vessels. The inner lumen is lined with lubricious PTFE to facilitate movement of guidewires and other devices.

CEREBASE™ DA Guide Sheath

CEREBASE™ DA Guide Sheath

Go Distal… Better trackability. Better support.*

ENTERPRISE™2 Vascular Reconstruction Device

ENTERPRISE™2 Vascular Reconstruction Device

Stability, Conformability and Ease of Use.

References

Important Safety Information / Essential Product Information​

Important information: Prior to use, refer to the instructions for use supplied with this device for indications, contraindications, side effects, warnings and precautions.
Caution: US law restricts this device to sale by or on the order of a physician.
This site is published by CERENOVUS which is solely responsible for its contents. It is intended for visitors from the United States.

Last Updated on 3/13/2024.

  1. Loh Y, Duckwiler GR, Onyx Trial I (2010) A prospective, multicenter, randomized trial of the Onyx liquid embolic system and N-butyl cyanoacrylate embolization of cerebral arteriovenous malformations. Clinical article. J Neurosurg 113 (4): 733-741.
  2. Velat GJ, Reavey-Cantwell JF, Sistrom C, Smullen D, Fautheree GL et al. (2008) Comparison of N-butyl cyanoacrylate and onyx for the embolization of intracranial arteriovenous malformations: analysis of fluoroscopy and procedure times. Neurosurgery 63 (1 Suppl 1): ONS73-78; discussion ONS78-80.
  3. FORSYTHE, P - DRG Data Source - September 2020.

US_CNV_HEMO_303295