Intended for healthcare professionals

LIGACLIP™ Endoscopic Rotating Multiple Clip Applier

The LIGACLIP™ Endoscopic Multiple Clip Applier is designed to deliver reduced clip scissoring, better in jaw security, and better security on vessel clip formation.1A

About this device

The LIGACLIP™ Endoscopic Rotating Multiple Clip Applier is a sterile, single patient use instrument designed to provide a means of ligation through appropriately-sized trocars. The instrument comes pre-loaded with 20 titanium clips that individually advance after each firing. The shaft is made of a low glare material that minimizes reflective distortion. Options include 8.8mm closed clip length for ER320 and 11.0mm for ER420.2

Features & benefits

LIGACLIP™ Endoscopic Rotating Multiple Clip Applier

Better In-Jaw security

LIGACLIP™ Endoscopic Rotating Multiple Clip Applier had a 35% stronger jaw than the previous clip applier. Stronger jaws allowed the user to achieve better clip formation.1,3B

LIGACLIP™ Endoscopic Rotating Multiple Clip Applier

Reduced clip scissoring

LIGACLIP™ Endoscopic Rotating Multiple Clip Applier had an 85% reduction in clip scissoring resulting in superior on vessel clip formation versus the previous clip applier.1C

LIGACLIP™ Endoscopic Rotating Multiple Clip Applier

Minimize vessel damage

LIGACLIP™ Endoscopic Rotating Multiple Clip Applier provides a visual reference of the quantity of clips remaining.2 Last clip lockout feature is designed to minimize vessel damage.4

Supporting documentation

PDF

LIGACLIP™ Endoscopic Rotating Multiple Clip Applier IFU

PDF

Ligation portfolio brochure

PDF

Ligation portfolio reference chart

PDF

Ligation portfolio cross reference guide
Select all (3)

Related products

LIGAMAX™ 5 Endoscopic Multiple Clip Applier

LIGAMAX™ 5 Endoscopic Multiple Clip Applier

Proper placement and application of clips in a surgical procedure can be impacted by multiple factors. LIGAMAX™ 5 Endoscopic Multiple Clip Applier is designed to mitigate clip dislodgment through greater in-jaw clip retention1 and on-structure clip security in the axial direction compared to other leading 5mm clip appliers.2,3

LIGACLIP™ Multiple Clip Applier

LIGACLIP™ Multiple Clip Applier

Designed for use in open procedures, the LIGACLIP™ Multiple Clip Applier (MCA) comes preloaded with 20-30 clips1 and offers a lockout feature that is designed to minimize vessel damage,2 as well as proprietary grooves on the clips designed for secure fixation and increased resistance to dislodgement of a formed clip.3

References

A. Benchtop testing for Loaded Torque Testing (LTT), comparing clip scissoring upper bound of 99% reliability at 95% confidence between predicate ER320 (n=32) to refreshed ER320 (n=32). Means of 0.06884 in. for predicate ER320 (n=32) to mean of 0.02034 in. for refreshed ER320, demonstrated a statistically significant improvement (n=32, p<0.001, @95% conf.) and Benchtop testing for post reliability jaw aperture, comparting jaw yield post foreseeable misuse upper bound of 90% reliability at 90% confidence between predicate ER320 (n=32) to refreshed ER320 (n=32). Means of 0.1871 in. for predicate ER320 (n=32) to mean of 0.1802 in. for refreshed ER320 demonstrated a statistically significant improvement (n=32, p<0.001, @95% conf.).

B. Benchtop testing for post reliability jaw aperture, comparing jaw yield post foreseeable misuse upper bound of 90% reliability at 90% confidence between previous device design ER320 (n=32) to redesigned device ER320 (n=32). Means of 0.1871 in. for previous device design ER320 (n=32) to mean of 0.1802 in. for redesigned device ER320 demonstrated a statistically significant improvement (n=32, p<0.001, @95% conf.).

C. Benchtop testing for Loaded Torque Testing (LTT), comparing clip scissoring upper bound of 99% reliability at 95% confidence between previous device design ER320 (n=32) to redesigned device ER320 (n=32). Means of 0.06884 in. for previous device design ER320 (n=32) to mean of 0.02034 in. for redesigned device ER320, demonstrated a statistically significant improvement (n=32, p<0.001, @95% conf.).

  1. Ethicon, Bedrock Test Summary. 07.23.2018. Windchill Document # PRC086355.
  2. LIGACLIP™ Endoscopic Rotating Multiple Clip Applier Instructions for Use. Ethicon, Inc.
  3. Ethicon, Bedrock EB3 DV Testing. 03.21.2019. Windchill Document #PRC082193
  4. FB29053 – LIGACLIP Multiple Clip Applier Fact Book-Product Criteria


For complete indications, contraindications, warnings, precautions, and adverse reactions, please reference full package insert. 


The third-party trademarks used herein are trademarks of their respective owners. 

US_SRG_LIGA_221968.1