ETHICON PROXIMATE™ Linear Cutters

For over 25 years, Johnson & Johnson MedTech’s Linear Cutter platform has delivered consistent, reliable staple lines compared to DST Series GIA.1-3,A,B,C The ETHICON PROXIMATE™ Linear Cutter is designed to provide dependable staple formation3C with multiple device lengths and reload options4 to meet the unique needs of each patient and procedure.

ETHICON PROXIMATE™ Linear Cutters

About this device

Properly formed staples are a key component of secure surgical stapling, but thick tissue can cause staples to become bent and malformed. ETHICON PROXIMATE™ Linear Cutters is designed to deliver controlled tissue compression from thin to thick tissue2 and provide four reload options to accommodate a broad range of tissue thicknesses.4

Specialties

Thoracic, Gastric, Gynecologic, Pediatric

Procedures

Colectomy, Small Bowel Resection, Gastrectomy, Lobectomy, Wedge Resection

ETHICON PROXIMATE™ Linear Cutters

Reduced risk of leaks

Unique jaw closure mechanism helps reduce risk of staple line leakage.1,2A The ETHICON PROXIMATE™ Linear Cutter had a 53% higher mean luminal leak pressure when compared to DST Series GIA.1,2B

ETHICON PROXIMATE™ Linear Cutters

Superior staple form

The ETHICON PROXIMATE™ Linear Cutter had 51% fewer malformed staples than DST Series™ GIA™ in thick tissue.3C

ETHICON PROXIMATE™ Linear Cutters

Wide tissue thickness range

Four reloads designed for a variety of tissue thicknesses and stapler lengths to provide the flexibility to address the needs of each patient.4

  • White cartridge: 55mm stapler
  • Gold cartridge: 75mm stapler
  • Blue cartridge: 55mm, 75mm, and 100mm
  • Green cartridge: 55mm, 75mm, and 100mm

Learn how to use this device

ETHICON PROXIMATE™ Linear Cutters

Supporting documentation

PDF

ETHICON PROXIMATE™ Linear Cutters IFU

PDF

ETHICON PROXIMATE™ Linear Cutters optimal device performance guide
Select all (1)

Related products

ECHELON LINEAR™ Cutter

Leaks can have a devastating impact for patients and hospitals. Compounding this challenge, increasing patient complexity in some open procedures further elevates the risk of leaks. The ECHELON LINEAR™ Cutter provided 47% fewer staple line leaks compared to the PROXIMATE™ Linear Cutter and GIA™ Stapler with Tri-Staple™ Technology.1A

References

A. PROXIMATE™ Line Cutter (TLC) had 78% fewer leaks at or below 100mm Hg compared to GIA8038S in benchtop testing of luminal leak pressure in an excised animal tissue model, p<0.001.


B. Benchtop testing of mean luminal leak pressure in an excised animal tissue model, DST80 92.3mmHg vs TLC75 141.3mmHg (p<0.001).


C. Benchtop testing of formed staples fired in porcine tissue over a 2mm-5mm range of tissue thickness (p<0.005).


  1. Ethicon, Leak Resistance Evaluation in the Harvested Canine Jejunum Using the Ethicon NTLC75, TLC75 and the Covidien DST GIA 80 Linear Cutters. 1/4/2017. Windchill Document # PSB004363.
  2. Ethicon, TLC Cam and Retention Pin Claims Memo. 01.31.2024. Windchill Document #501505410.
  3. Ethicon, Linear Cutter Competitive Evaluation - SFQ. 03.28.2016. Windchill Document #PRC072578.
  4. ETHICON PROXIMATE™ Linear Cutter Instruction for Use. Ethicon, Inc.

For complete indications, contraindications, warnings, precautions, and adverse reactions, please reference full package insert. 


The third-party trademarks used herein are trademarks of their respective owners.  


US_SRG_STAP_117711.1