CARTOSOUND™ FAM Module
Powered by Artificial Intelligence, the CARTOSOUND™ FAM Module reconstructs the left atrial (LA) anatomy on the CARTO™ 3 System with a few rotations of your ultrasound catheter, eliminating the need for manual contouring.*1,2
Features & benefits

Automatic delineation
The CARTOSOUND™ FAM Module automatically delineates key LA structures, simplifying your workflow.2
In addition to the 3D volume reconstructed, the CARTOSOUND™ FAM Module identifies the LA anatomies using automatic contouring overlaid on the corresponding 2D ultrasound frames and provides 3D automatic segmentation and tagging of the relevant anatomies.3,4

Simplified workflow
CARTOSOUND™ FAM provides a simplified workflow experience driven by Frame Gating and Verified Respiration filtering.2
Incorporating a Deep Learning (DL) algorithm, the CARTOSOUND™ FAM Module simplifies the workflow of ultrasound-based cardiac anatomy mapping by eliminating manual contouring and providing an enhanced Fast Anatomical Mapping (FAM) workflow.2
An integrated system

SOUNDSTAR™ Ultrasound Catheter

VARIPULSE™ Platform

QDOT MICRO™ Catheter

Dr. Luigi Di Biase
M.D., PhD, FACC, FHRS, FESC
Supporting documentation
Related products

CARTO ELEVATE™ Module
CARTO™ 3 System V8 brings advanced mapping capabilities with enhanced signal analysis tools, improved substrate characterization and utilization of ultrasound technology.
.png?width=3840&quality=90&format=webp)
CARTO PRIME™ Module
CARTO™ 3 System and the CARTO PRIME™ Module offers advancement in 3D mapping technology. From signals to diagnosis, across a wide range of electrophysiology procedures, we are re-framing the future of electrophysiology.
.jpg?width=3840&quality=90&format=webp)
CARTO™ LAM Module
References
*CARTOSOUND™ FAM Module uses Deep Learning, which is a subset of AI.
- Di Biase L, Zou F, Lin AN, et al. Feasibility of Three-Dimensional Artificial Intelligence Algorithm Integration with Intracardiac Echocardiography for Left Atrial Imaging During Atrial Fibrillation Catheter Ablation. Europace. 2023 Aug 2025.
- CARTOSOUND™ FAM Module Instructions for Use. UG_5462-00A.
- Akerström F, Drca N, Urstad MJ, Braunschweig F. Feasibility of a novel algorithm for automated reconstruction of the left atrial anatomy based on intracardiac echocardiography. Pacing Clin Electrophysiol. 2022 Nov;45(11):1288-1294.
- Di Biase L, Zou F, Lin AN, et al. Feasibility of Three-Dimensional Artificial Intelligence Algorithm Integration with Intracardiac Echocardiography for Left Atrial Imaging During Atrial Fibrillation Catheter Ablation. Europace. 2023 Aug 2;25(9):euad211
Important information: Prior to use, refer to the instructions for use supplied with this device for indications, contraindications, side effects, warnings and precautions.
Caution: US law restricts this device to sale by or on the order of a physician.
The Johnson & Johnson and its affiliates QDOT MICRO™ Catheters and related accessory devices are indicated for catheter-based cardiac electrophysiological mapping (stimulating and recording) and, when used in conjunction with a compatible radiofrequency generator, for the treatment of:• Type I atrial flutter in patients age 18 or older.• Drug refractory recurrent symptomatic paroxysmal atrial fibrillation, when used with compatible three-dimensional electroanatomic mapping systems. The Johnson & Johnson and its affiliates QDOT MICRO™ Catheters provide real-time measurement of contact force between the catheter tip and heart wall, as well as location information when used with CARTO™ 3 Navigation System.
This site is published by Johnson & Johnson and its affiliates. which is solely responsible for its contents. It is intended for visitors from the United States.
US_ELP_NAVI_347539.1

.png?width=3840&quality=90&format=webp)