CARTOSOUND™ FAM Module

Powered by Artificial Intelligence, the CARTOSOUND™ FAM Module reconstructs the left atrial (LA) anatomy on the CARTO™ 3 System with a few rotations of your ultrasound catheter, eliminating the need for manual contouring.*1,2

Features & benefits

Automatic delineation

Automatic delineation

The CARTOSOUND™ FAM Module automatically delineates key LA structures, simplifying your workflow.2


In addition to the 3D volume reconstructed, the CARTOSOUND™ FAM Module identifies the LA anatomies using automatic contouring overlaid on the corresponding 2D ultrasound frames and provides 3D automatic segmentation and tagging of the relevant anatomies.3,4

Simplified workflow

Simplified workflow

CARTOSOUND™ FAM provides a simplified workflow experience driven by Frame Gating and Verified Respiration filtering.2

Incorporating a Deep Learning (DL) algorithm, the CARTOSOUND™ FAM Module simplifies the workflow of ultrasound-based cardiac anatomy mapping by eliminating manual contouring and providing an enhanced Fast Anatomical Mapping (FAM) workflow.2 

An integrated system

SOUNDSTAR™ Ultrasound Catheter

SOUNDSTAR™ Ultrasound Catheter

VARIPULSE™ Platform

VARIPULSE™ Platform

QDOT MICRO™ Catheter

QDOT MICRO™ Catheter

Dr. Luigi Di BiaseM.D., PhD, FACC, FHRS, FESC
By eliminating the need for manual contouring, the new system represents a new approach to anatomy creation, improving the efficiency of the procedure workflow.

Dr. Luigi Di Biase
M.D., PhD, FACC, FHRS, FESC

Supporting documentation

PDF

CARTO™ V8 Brochure
Select all (1)

Related products

CARTO ELEVATE™ Module

CARTO ELEVATE™ Module

CARTO™ 3 System V8 brings advanced mapping capabilities with enhanced signal analysis tools, improved substrate characterization and utilization of ultrasound technology.

CARTO PRIME™ Module

CARTO PRIME™ Module

CARTO™ 3 System and the CARTO PRIME™ Module offers advancement in 3D mapping technology. From signals to diagnosis, across a wide range of electrophysiology procedures, we are re-framing the future of electrophysiology.

CARTO™ LAM Module

CARTO™ LAM Module

The CARTO™ Late Annotation Mapping (LAM) Module may improve mapping annotation accuracy of both low-voltage amplitude signals and local abnormal ventricular activities (LAVAs)*1

References

*CARTOSOUND™ FAM Module uses Deep Learning, which is a subset of AI.

  1. Di Biase L, Zou F, Lin AN, et al. Feasibility of Three-Dimensional Artificial Intelligence Algorithm Integration with Intracardiac Echocardiography for Left Atrial Imaging During Atrial Fibrillation Catheter Ablation. Europace. 2023 Aug 2025.
  2. CARTOSOUND™ FAM Module Instructions for Use. UG_5462-00A.
  3.  Akerström F, Drca N, Urstad MJ, Braunschweig F. Feasibility of a novel algorithm for automated reconstruction of the left atrial anatomy based on intracardiac echocardiography. Pacing Clin Electrophysiol. 2022 Nov;45(11):1288-1294.
  4. Di Biase L, Zou F, Lin AN, et al. Feasibility of Three-Dimensional Artificial Intelligence Algorithm Integration with Intracardiac Echocardiography for Left Atrial Imaging During Atrial Fibrillation Catheter Ablation. Europace. 2023 Aug 2;25(9):euad211


Important information: Prior to use, refer to the instructions for use supplied with this device for indications, contraindications, side effects, warnings and precautions.


Caution: US law restricts this device to sale by or on the order of a physician.


The Johnson & Johnson and its affiliates QDOT MICRO™ Catheters and related accessory devices are indicated for catheter-based cardiac electrophysiological mapping (stimulating and recording) and, when used in conjunction with a compatible radiofrequency generator, for the treatment of:• Type I atrial flutter in patients age 18 or older.• Drug refractory recurrent symptomatic paroxysmal atrial fibrillation, when used with compatible three-dimensional electroanatomic mapping systems. The Johnson & Johnson and its affiliates QDOT MICRO™ Catheters provide real-time measurement of contact force between the catheter tip and heart wall, as well as location information when used with CARTO™ 3 Navigation System.


This site is published by Johnson & Johnson and its affiliates. which is solely responsible for its contents. It is intended for visitors from the United States.

US_ELP_NAVI_347539.1