Outcomes & Evidence
Two-Year Outcomes following Total Hip Replacement with the ACTIS™ Hip
See the data on patient outcomes after two years with the ACTIS™ Hip vs. other replacement stems.
Four-Year Evidence Update Shows 99.8 Stem Survivorship with the ACTIS™ Hip
See additional data on survivorship at 4 years with the ACTIS™ Hip and how patients surgeons saw low revision rates when implanted with the ACTIS™ Hip.
Features & Benefits

Variable Triple-Tapered Geometry
The ACTIS™ Hip Stem is tapered in three separate planes to aid in the short and long-term stability of the stem.

Medial Collar Option
The medial collar option on the ACTIS Hip Stem provides secondary stability for immediate weight bearing and reduces the potential of subsidence.2

DUOFIX™ HA Coating
DUOFIX™ HA Coating combines POROCOAT™ Porous Coating, which allows for biological fixation to bone, with the addition of a 35-micron layer of HA coating.4

Bone Preserving Philosophy
ACTIS Hybrid Broaches feature a compaction broach pattern on the anterior/posterior sides and extraction teeth on the medial/lateral sides of the broach, allowing for preservation of patient anatomy while ensuring adequate fit in the canal.
Compare Products
Compare Products
Featured Product |
||
---|---|---|
![]() |
![]() |
|
ACTIS™ Total Hip Solutions |
SUMMIT™ Tapered Hip System |
|
Material |
Ti6AI4V Proximal POROCOAT™ coating/extensively HA-coated 35µm | Ti6AI4V Proximal POROCOAT™ coating/extensively HA-coated 35µm |
Revision/Standard |
Standard | Standard |
Cemented/Cementless |
Collar and Collarless uncemented | Collarless uncemented |
Standard/High Offset |
13 sizes (Standard/HO) | 10 sizes (Standard, HO) |
Offset Range |
36-54 mm | 36-54 mm |
Shell Style |
EMPHASYS™ Acetabular Solutions, PINNACLE™ Acetabular Solutions | EMPHASYS™ Acetabular Solutions, PINNACLE™ Acetabular Solutions |
Screw Flange |
NA | NA |
Product Resources
Clinical Resources
References
- Huff et al. (2015). Femoral Prosthesis with Insertion/Extraction Feature (U.S. Patent No. 9084685B2). U.S. Patent and Trademark Office
- DePuy Synthes Hamburg University Actis Cadaveric Testing – Primary Stability of the Eclipse Hip. 8/5/2015. Windchill Document #103156243
- Royalty COE Report, ACTIS WW implantations YTD, 2016-2022
- Pillar RM. Powder metal-made orthopaedic implants with porous surface for fixation by tissue ingrowth Clin Orthop 1983:150
Please refer to the instructions for use for a complete list of indications, contraindications, warnings and precautions. The third-party trademarks used herein are the trademarks of their respective owners.
094331-210428 DSUS