CONFIDENSE™ Module

The CONFIDENSE™ Module is a collection of features that aid in the acquisition and understanding of CARTO™ 3 Maps. The collection of features include Continuous Mapping feature, Tissue Proximity Technology, Wavefront Mapping Annotation, and Map Consistency Display.

CONFIDENSE™ Module

Features & benefits

Continuous Mapping

Continuous Mapping

The Continuous Mapping Feature enables continuous acquisition of EA points which meet a set of pre-defined filters.

Tissue Proximity Technology

Tissue Proximity Technology

With Tissue Proximity Technology, the CARTO™ 3 System uses impedance measurements to determine an electrode's proximity to cardiac tissue. If the electrode is in the proximity of the tissue, the electrode is considered to be touching.
The proximity status can be used for

the following features:

  • Tissue Proximity Indication in the map viewers, Point List, and Selected Point Viewer
  • MEM point acquisition based on Tissue Proximity Filter
Wavefront Mapping

Wavefront Mapping

The Wavefront Mapping Annotation uses an algorithm to search for the greatest negative deflection (-dV/dt) in each distal unipolar signal and mark it for the local activation time calculation.

Map Consistency Display

Map Consistency Display

The Map Consistency Display is a point filter that identifies points whose Local Activation

Time (LAT) values are not consistent with the LAT values of neighboring points. When this filter is applied, the CARTO™ 3 System marks these outliers.

An integrated workflow

OCTARAY™ Mapping Catheter with TRUEref™ Technology

OCTARAY™ Mapping Catheter with TRUEref™ Technology

OPTRELL™ Mapping Catheter

OPTRELL™ Mapping Catheter

VARIPULSE™ Catheter

VARIPULSE™ Catheter

Related products

CARTO ELEVATE™ Module

CARTO ELEVATE™ Module

CARTO™ 3 System V8 brings advanced mapping capabilities with enhanced signal analysis tools, improved substrate characterization and utilization of ultrasound technology.

CARTO™ LAM Module

CARTO™ LAM Module

The CARTO™ Late Annotation Mapping (LAM) Module may improve mapping annotation accuracy of both low-voltage amplitude signals and local abnormal ventricular activities (LAVAs)*1
CARTOSOUND™ FAM Module

CARTOSOUND™ FAM Module

Powered by Artificial Intelligence, the CARTOSOUND™ FAM Module reconstructs the left atrial (LA) anatomy on the CARTO™ 3 System with a few rotations of your ultrasound catheter, eliminating the need for manual contouring.

References

No references for this product.


Important information: Prior to use, refer to the instructions for use supplied with this device for indications, contraindications, side effects, warnings and precautions. Caution: US law restricts this device to sale by or on the order of a physician.


DO NOT use OCTARAY™ Mapping Catheter with TRUEref™ Technology or OPTRELL™ Mapping Catheter with TRUEref™ Technology in patients with prosthetic valves.

US_ELP_NAVI_406499