ENDOPATH XCEL™ Trocars with OPTIVIEW™ Technology
Trocars are the first point of contact into a patient and need to do many jobs - maximize visibility and maneuverability, enable surgical flow, and minimize exposure to pneumoperitoneum gas. ENDOPATH XCEL™ Trocars with OPTIVIEW™ Technology are designed to reduce smudging of the endoscope upon reinsertion by wiping, wicking and absorbing fluid that builds up inside the trocar.1,2A
About this device
ENDOPATH XCEL™ Trocars with OPTIVIEW™ Technology are surgical instruments used in minimally invasive surgery that function as a portal for subsequent insertion of other endoscopic instruments. The proprietary OPTIVIEW™ Technology wipes, wicks, and absorbs bodily fluid and debris from the endoscope shaft as it is removed from the trocar.3-6
Select from a versatile portfolio: bladeless, dilating tip, blunt tip, and universal sleeve options, each available in 5mm and 12mm sizes.
Features & benefits

Reliable control
ENDOPATH XCEL™ Trocars with OPTIVIEW™ Technology are the only trocars that reduce rewipes of the scope upon reinsertion after cleaning.1,2A They have the most effective smudge mitigation vs. leading trocars.1,2A

Reduced smudging
Provides a controlled and predictable entry. ENDOPATH XCEL™ Trocars had higher abdominal wall retention force7,8BC and lower insertion force1,2,7AD than Applied or Medtronic trocars.

Lower leak rates
ENDOPATH XCEL™ 5mm Trocars had the lowest and most consistent leak rates of leading 5mm trocars.9EF
Learn how to use this device
Supporting documentation
Related products

ENDOPATH XCEL™ Trocars
Trocars are the first point of contact into a patient during minimally invasive procedures and need to do many jobs - maximize visibility and maneuverability, enable surgical flow, and minimize exposure to pneumoperitoneum gas. ENDOPATH XCEL™ Trocars are designed to offer the control1,2A-D and consistency3-5E-G needed throughout the procedure from open to close.
References
A. In bench top tests comparing mean number of insertions for 5mm trocars out of 10 insertions with a quality index score of 92 or higher for 2B5LT (6.4) to CFR03/CTR03/CTF03 (0.5), VS101005 (0.4), p<0.05. In bench top tests comparing mean number of insertions for 12mm trocars out of 15 insertions with a quality index score of 92 or higher for 2B12LT (11.6) to CTF73/CFF73/CFR73/C0R47 (0.4), VS101012P (1.6), p<0.05. Quality index score of 92 or higher indicates a less than 20% chance of having to re‐wipe the endoscope lens due to trocar induced smudging.
B. In pre-clinical testing, average abdominal wall retention force, B12LT/2B12LT (19.4lbs) vs VS101012P (7.9lbs), p<0.001.
C. In pre-clinical testing, average abdominal wall retention force, B5LT/2B5LT (9.8lbs) vs CTF03 (5.9lbs), p<0.001.
D. In pre-clinical testing, average abdominal wall insertion force, B12LT/2B12LT (18.3lbs) vs VS101012P (27.7lbs), p<0.001
E. On a benchtop test measuring leak rate with a 4.7mm probe inserted, Ethicon B5LT leaked significantly less than Medtronic ONB5STF, Applied Medical CFR03 and Applied Medical CTR03. B5LT leak rate distribution was significantly less than CTR03, although the medians were both zero.
F. On a benchtop test measuring leak rate with a 4.7mm probe, B5LT leak rate standard deviation was 82% less than ONB5STF, 93% less than CFR03 and 88% less than CTR03.
- Ethicon, Competitive Tests of Access System Quality Image. 10.10.2012. Windchill Document #PRC049012.
- Ethicon, HER-112 Hermes Competitive Quality Index Testing. 05.22.2013. Windchill Document #PRC056628.
- ENDOPATH XCEL™ with OPTIVIEW™ Technology Universal Sleeve Instructions for Use. Ethicon, Inc.
- ENDOPATH® XCEL™ with OPTIVIEW™ Technology Bladeless Trocar Instructions for Use. Ethicon, Inc.
- ENDOPATH XCEL™ WITH OPTIVIEW™ Technology Blunt Tip Trocar Instructions for Use. Ethicon, Inc.
- ENDOPATH XCEL™ WITH OPTIVIEW™ Technology Dilating Tip Trocar Instructions for Use. Ethicon, Inc.
- Ethicon, Competitive Device Evaluation Comparing Ethicon XCEL Trocar Insertion and Retention Forces to the Covidien VersaStep Trocar. 01.06.2017. Windchill Document #PSB004559.
- Ethicon, Competitive Device Evaluation Comparing Ethicon XCEL Trocar Insertion and Retention Forces to the Covidien Versaport, Applied Medical Kii Trocars. 01.31.2018. Windchill Document #PSB004498.
- Ethicon, Competitor Trocar Leak Performance Benchmarking. 03.24.2023. Windchill Document #PRC096502.
For complete indications, contraindications, warnings, precautions, and adverse reactions, please reference full package insert.
The third-party trademarks used herein are trademarks of their respective owners.
US_SRG_ACSS_221861.1