CARTO VIZIGO™ Bi-Directional Guiding Sheath

The CARTO VIZIGO™ Bi-Directional Guiding Sheath puts electrophysiologists in command for the ultimate CARTO™ 3 System experience. Confidence in procedures with sheath visualization, efficiencies and optimized performance.

The VIZIGO™ Sheath allows for sheath visualization on the CARTO™ 3 System map during a procedure without depending solely on fluoroscopy. Visualization with the CARTO VIZIGO™ Bi-Directional Guiding Sheath may enhance efficiency during mapping and positioning of the ablation catheter.

Features & benefits

A close-up view of a CARTO™ 3 System monitor with the CARTO VIZIGO™ Bi-Directional Guiding Sheath visualized inside the anatomy.

Visualization

The VIZIGO™ Sheath allows for sheath visualization on the CARTO™ 3 System map during a procedure without depending solely on fluoroscopy.

A visualization on CARTO™ software shows the CARTO VIZIGO™ Bi-Directional Guiding Sheath.

Efficiency

  • Sheath visualization aids in understanding the spatial relationship between the catheter and the sheath during navigation1
  • Sheath visualization also aids in understanding the orientation during catheter manipulation
A detailed close-up image of the CARTO VIZIGO™ Guiding Sheath tip.

Performance

  • Braided shaft with silicone coating to enable good torque and friction response
  • Ergonomic handle design

An integrated system

References

  1. Wakamatsu Y, et al. Impact of the combined use of intracardiac ultrasound and a steerable sheath visualized by a 3D mapping system on pulmonary vein isolation. Pacing Clin Electrophysiol. 2021 Apr;44(4):693-702. doi: 10.1111_pace.14194. Epub 2021 Mar 11. PMID: 33595100.

DO NOT use OCTARAY™ or OPTRELL™ Mapping Catheters with TRUEref™ Technology in patients with prosthetic valves.


The Johnson & Johnson and its affiliates QDOT MICRO™ Catheters and related accessory devices are indicated for catheter-based cardiac electrophysiological mapping (stimulating and recording) and, when used in conjunction with a compatible radiofrequency generator, for the treatment of:• Type I atrial flutter in patients age 18 or older.• Drug refractory recurrent symptomatic paroxysmal atrial fibrillation, when used with compatible three-dimensional electroanatomic mapping systems.The Johnson & Johnson and its affiliates QDOT MICRO™ Catheters provide real-time measurement of contact force between the catheter tip and heart wall, as well as location information when used with CARTO™ 3 Navigation System.


Always verify catheter tip location using common clinical practice for real-time verification (inspection of IC signals, direct imaging guidance such as fluoroscopy or ultrasound, etc.) and consult the CARTO™ 3 System User Guide regarding recommendations for fluoroscopy use.


Canpolat, U. et al (2020). State of Fluoroless Procedures in Cardiac Electrophysiology Practice. J Innov Cardiac Rhythm Management. 11(3), 4018–4029.Sommer, P. et al (2018) Safety profile of near-zero fluoroscopy atrial fibrillation ablation with non-fluoroscopic catheter visualization: experience from 1000 consecutive procedures, EP Europace, Volume 20, Issue 12, Pages 1952–1958.


Important information: Prior to use, refer to the instructions for use supplied with this device for indications, contraindications, side effects, warnings and precautions. Caution: US law restricts this device to sale by or on the order of a physician.


This site is published by Johnson & Johnson and its affiliates, which is solely responsible for its contents. It is intended for visitors from the United States. Last Updated on 09/15/2025.


US_ELP_ACSS_407859