Skip to main content

Intended for Healthcare Professionals

Johnson and Johnson logo graphic link
/en-US
  • acclarent logo
  • biosense webster logo
  • cerenovus jjmdc logo
  • DePuy Synthes
  • Ethicon Logo
  • Mentor Logo

Intended for HCPs

Intended for Healthcare Professionals

Secondary nav block

DePuy Synthes Logo
  • Specialties
    • All Specialties
    • Craniomaxillofacial (CMF)
    • Foot & Ankle
    • Hip
    • Knee
    • Shoulder
    • Spine
    • Sports Medicine
    • Trauma & Extremities
    • Veterinary
  • Procedures
    • All Procedures
    • Hip
      • Hip Arthroplasty
    • Knee
      • Anterior Cruciate Ligament Reconstruction (ACL) Soft Tissue
      • Knee Replacement
      • Sports Medicine
        • BTB ACL Reconstruction
    • Sports Medicine
      • Arthroscopic Anatomic Glenoid Reconstruction
      • BTB ACL Reconstruction
      • Lower Trapezius Transfer
  • Product Hub
  • Services
    • All Services
      • Investigator-Initiated Studies
      • J&J Innovation
    • ASC Capabilities
    • Advance Case Management
    • Loaner Program
    • MatrixRIB Care Program
    • Service Care
  • News
  • Patients
    • Knee Replacement
    • Patient Home
    • VELYS Patient Home
  1. Home
  2. Products
  3. ATTUNE™ Revision Knee System

TOTAL KNEE ARTHROPLASTY

ATTUNE™ Revision Knee System

TOTAL KNEE ARTHROPLASTY

ATTUNE™ Revision Knee System

The ATTUNE™ Revision Knee System provides a modern revision knee system scientifically designed for STABILITY IN MOTION™ that more closely matches the kinematics of the natural knee to allow for functional knee restoration and improve patient satisfaction.1,2 The system is designed to simplify the complex, with joint line restoration and flexion gap solutions, streamlined patient-specific workflows, intentional system continuity, and the power of KINCISE™ technology.

Get In Touch with a Sales Consultant
Two ATTUNE Revision Knee System implants

IMAGES

Two ATTUNE Revision Knee System implants

Key Resources

scalpel icon

Surgical Technique Guide

View Guide PDF
paper with exclamation mark icon

Instructions for Use

View Instructions PDF

Unfortunately we can’t detect an electronic copy of the Instructions for Use (IFU) you are seeking. You can find instructions on how to use this product included with the product packaging.

If you need an additional copy of the IFU, you can:

  1. Search the global e-ifu.com website, 
  2. Contact your sales consultant, or 
  3. Reach out to us directly.
book icon

Product Overview

View Brochure PDF
ATTUNE Revision Knee System

PROVEN SUCCESS

ATTUNE™ Revision Evidence

The DePuy Synthes Rotating Platform and Sleeve Technology combination has demonstrated 98-100% survivorship at 5 years and 97.8% at 10 years.3-5 We’re proud of this legacy of proven success that enables surgeons to provide long-lasting mobility to their patients.

KINCISE™ Surgical Automated System with ATTUNE™ Revision Broach Adapter

ENHANCED WORKFLOWS

Integrating KINCISE™ System Technology

The KINCISE™ System allows for constant and consistent application of energy, augments surgical skills, and aids in reducing surgeon fatigue and work-related injuries.7

The KINCISE™ Surgical Automated System, in conjunction with the KINCISE™ System ATTUNE™ Revision Broach Adapter, can now be used for ATTUNE™ Revision RP tibial and femoral sleeve bone preparation.

Explore KINCISE™ Surgical Automated System

Why ATTUNE™ Knee Solutions?

Why replace, when you can restore? ATTUNE™ Knee Solution products are designed to not just facilitate successful total knee arthroplasty (TKA) procedures but restore patients back to their original freedom of movement through innovative implants, powerful fixation tools, and patient-specific techniques.

Two ATTUNE Revision Knee System implants

ATTUNE™ Revision Knee System

The ATTUNE™ Revision Knee System delivers kinematically advanced revision implants with proprietary design features to address key challenges in revision knee arthroplasty.

X-ray image of knee with knee implant

Patient-Specific Techniques

The ATTUNE™ system includes simplified, patient-specific solutions with intentional system continuity so you can customize your approach to fit your unique patient.

KINCISE™ Surgical Automated System with ATTUNE™ Revision Broach Adapter

ATTUNE™ Knee System + KINCISE™ Surgical Automated System

The KINCISE™ System ATTUNE™ Revision Broach Adapter, along with the ATTUNE™ Revision Knee System, is designed to automate the sleeve-preparation process for revision knee surgery.

Eight different ATTUNE implants in a row from smallest to largest

IMPROVING KNEE REVISION

Simplicity by Design

ATTUNE™ is designed to simplify the complex through intelligent, flexible design and efficient surgical techniques. The intentional system continuity throughout the ATTUNE™ lineup and a consistent sleeve preparation process means your surgical team can streamline their learning and apply it to a wide range of patient cases.  

Features & Benefits

You are entering a rotating card carousel. Navigate the items by using the previous/next buttons.

Cross-section diagram showing the ATTUNE GRADIUS curve

ATTUNE GRADIUS™ Curve

The patented ATTUNE GRADIUS™ Curve is a gradually reducing femoral radius designed to provide a smooth transition from stability to rotational freedom through a patient’s range of motion.

Diagram demonstrating the SOFCAM Contact technology

SOFCAM™ Contact

The proprietary S-curve of the SOFCAM™ Contact is designed to provide a smooth engagement for gradual femoral rollback and stability in flexion, while reducing stresses transferred to the tibial spine.

Close-up image of groove in knee implant

GLIDERIGHT™ Articulation

GLIDERIGHT™ Articulation encompasses a trochlear groove designed to accommodate patient variation and soft tissue interaction, and patella components designed to optimize patella tracking while maintaining bone coverage.

LOGICLOCK Tibial Base

LOGICLOCK™ Tibial Base

The LOGICLOCK™ Tibial Base has a patented central locking design that provides the architecture for the system to optimize kinematics, while reducing backside micromotion to the lowest reported levels in the industry.6

Tibial and femoral sleeves

METAPHYSEAL Sleeves

The ATTUNE Revision Knee System offers a range of Tibial and Femoral Sleeves that are designed to address varying degrees of cavitary bone loss as well as achieve fixation and load distribution closer to the joint line. Both the Tibial and Femoral Sleeves are available in Cemented or POROCOAT™ Porous Coated fixation options.

ATTUNE knee implant

Rotating Platform Technology

The ATTUNE™ Revision Rotating Platform Tibial Base was designed based on the successful clinical heritage of the legacy DePuy Synthes SIGMA TC3 RP and M.B.T. Revision Knee Systems

ATTUNE™ Revision Knee System and KINCISE™ Automated Impactor

Follow Dr. Ryan Nunley and Dr. Cara Cipriano as they take us through the Surgical Technique for ATTUNE™ Revision Knee System using the KINCISE™ Automated Impactor.

View J&J Institute

Supporting Documentation

Evidence
Evidence

Evidence

  • ATTUNE Revision RP Outcomes
    PDF Icon

    View PDF

  • ATTUNE Revision Fixed Bearing System Brochure
    PDF Icon

    View PDF

  • ATTUNE Revision Rotating Platform System Brochure
    PDF Icon

    View PDF

  • Select all documents (3)
S-ROM® NOILES™ Rotating Hinge Knee System

S-ROM® NOILES™ Rotating Hinge Knee System 

Visit Page
LPS™ Limb Preservation System

LPS™ Limb Preservation System

Visit Page

References

  1. Fitzpatrick, C.K., Clary, C.W., Rullkoetter, P.J. (2012b, February). The influence of design on TKR mechanics during activities of daily living. ORS Annual Meeting, Poster #2034.
  2. Clary, C.W., Fitzpatrick, C.K., Maletsky, L.P., Rullkoetter, P.J. (2012a, February). Improving dynamic mid-stance stability: an experimental and finite element study. ORS Annual Meeting, Poster #1044.
  3. Bloch BV, Shannak OA, Palan J, Phillips JRA, James PJ. Metaphyseal Sleeves in Revision Total Knee Arthroplasty Provide Reliable Fixation and Excellent Medium to Long-Term Implant Survivorship. J Arthroplasty. 2020;35(2):495-499. doi:10.1016/j.arth.2019.09.027.
  4. Floría-Arnal LJ, Gómez-Blasco A, Roche-Albero A, Panisello-Sebastia JJ, MartinMartinez A, Martin-Hernández. Tibial tray cementation is not necessary for knee revision with titanium metaphyseal sleeves: a mid-term prospective study in AORI 2B defects. Knee Surg Sports Traumatol Arthrosc. 2020. Doi:10.1007/s00167-020-06185-0.
  5. van Loon C, Meermans G, Baas N, et al. Early recovery rate after a new design total knee arthroplasty (TKA): a prospective, multicenter cohort of 200 cases. 2nd World Arthroplasty Congress; April 19-21, 2018; Rome, Italy.
  6. Leisinger, S., Hazebrouck, S., Deffenbaugh, D., Heldreth, M. (2011). Advanced fixed bearing TKA locking mechanism minimizes backside micromotion. International Society for Technology in Arthroplasty (ISTA) Annual Meeting.
  7. Ferrari E, Khan M, Mantel J, Wallbank R. The assessment of muscle fatigue in orthopedic surgeons, by comparing manual versus automated broaching in simulated total hip arthroplasty. Proc Inst Mech Eng H. 2021 Jul 20:9544119211034386. doi: 10.1177/09544119211034386. Epub ahead of print. PMID: 34281446.

Please refer to the instructions for use for a complete list of indications, contraindications, warnings and precautions.

094325-220823

© DePuy Synthes 2022. All Rights Reserved. This site is published by the DePuy Synthes Companies, which are solely responsible for its content. This site is governed solely by applicable U.S. laws and governmental regulations. This site is for visitors from the United States. The third party trademarks used herein are the trademarks of their respective owners.

DePuy Synthes Logo

About

-

  • About Us
  • Our History
  • News & Media
  • Grants & Giving
  • Innovation Center

Useful Links

-

  • Instructions for Use (IFU)
  • Johnson & Johnson Institute
  • Reimbursement Resources
  • Investigator Initiated Studies

Legal

-

  • CA Compliance
  • ASR Recall

Connect

-

  • . . . .
  • Contact Us
  • Online Ordering
  • Inventory Management (eSIMS)
  • Careers
Johnson and Johnson logo
Johnson & Johnson
  • Privacy Policy
  • Legal Notice
  • Do Not Sell or Share My Personal Information
  • Contact Us
  • J&J Institute
  • Accessibility Statement
  • Cookie Policy
English (United States)

© Medical Device Business Services, Inc. 2021-2023. All rights reserved.

This information is intended for use by customers, patients, and healthcare professionals in the United States only. We recognize that the Internet is a global communications medium; however, laws, regulatory requirements, and product information for medical products can vary from country to country. The product information included here may not be appropriate for use outside the United States, and the information from other sites you visit may not be appropriate for use in the United States.

You are about to leave jnjmedtech.com. By clicking to continue, you will be taken to a web site governed by their own Legal and Privacy Policies.

Yes, Continue to External Site No, Stay Here