SECURESTRAP™ Absorbable Strap Fixation Device
Tissue capture, penetration and holding strength at multiple deployment angles are important factors when selecting a fixation device for hernia repair. SECURESTRAP™ Absorbable Strap Fixation Device is a market leading fixation device1A designed for acute holding strength at various deployment angles.2,3
About this device
SECURESTRAP Absorbable Strap Fixation Device is available with 25 or 12 synthetic absorbable straps, preloaded into the device’s 36 cm long shaft. The device is designed for introduction and use through a 5 mm or larger laparoscopic port sleeve. The straps are made of a blend of polydioxanone and an L-lactide/glycolide copolymer, with an inserted length of 6.7mm.
Specialties
Hernia
Procedures
Laparoscopic Ventral Repair, Laparoscopic Inguinal Repair
Features & benefits

Unique strap design
It has a uniqueB, absorbable “strap” design that uses 2 points of fixation to straddle mesh pores and fibers.4-6 The low-profile strap is designed to reduce exposure to viscera.7

Holding strength
Each strap ‐ from the first to the last ‐ deploys with similar force, providing the reliability you need.8,9 SECURESTRAP™ Absorbable Strap Fixation Device allows for appropriate tissue capture to provide acute holding strength at 30°, 45°, and 60° deployment angles.2,3

Minimal pain
Proven to get patients back to their lives with minimal to no pain.10 In a study of 56 patients from the International Hernia Mesh Registry (IHMR), SECURESTRAP™ Absorbable Strap Fixation Device was shown in a preliminary study of patients from the International Hernia Mesh Registry (IHMR) to be safe and provide an improvement in pain levels compared to baseline level.11
Supporting documentation
Related products

SECURESTRAP™ Open Absorbable Strap Fixation Device
SECURESTRAP™ Open Absorbable Strap Fixation Device is the first absorbable fixation device purposefully designed for the unique challenge of open ventral hernia repair.1 It features a low profile design to reduce exposure to viscera.2 Each strap, from the first to the last, deploys with a similar force — providing the reliability you need.3

PROCEED™ Surgical Mesh
Mesh optimized for strength and performance are critical for Intraperitoneal only mesh repair (IPOM) procedures. Trusted by surgeons for over a decade,A PROCEED™ Surgical Mesh is a macroporous, partially absorbable, tissue-separating mesh, combining large-pore mesh knitted with monofilament fibers and natural, absorbable tissue separating technology.1,2B

ULTRAPRO ADVANCED™ Macroporous Partially Absorbable Mesh
Built on the proven technology of ULTRAPRO™ Macroporous Partially Absorbable Mesh1, ULTRAPRO ADVANCED™ is designed to help optimize patient outcomes2,3and ease of use4,5 in inguinal and ventral hernia repair. Physiologically designed for comfortable healing6-8, it features a unique knitted mesh construction to promote good tissue ingrowth/integration.9A
References
A. Using 2021 US market data.
B. Based on currently available fixation constructs as of February, 2022.
C. Based on benchtop testing in a porcine flank.
1. Millennium Research Group. “Medtech 360 Hernia Repair Devices | Market Insights | Global | 2021”, 2020.
2. Ethicon, AST 2010‐0199 Ethicon SECURESTRAP™ Angle fire competitive test. April 2010.
3. Ethicon, SEC‐339‐11‐8‐13 Ethicon Comparison of Acute Holding Strength of an Absorbable Strap, August 2011.
4. Ethicon, A preclinical evaluation of tissue fixation and mechanical strength of the ETHICON SECURESTRAP™ absorbable 5mm strap fixation device (preclinical study). September 2011.
5. Ethicon, ORN‐50‐3090 Rev 11,Tack Comparison, 03/06/2008.
6. Medtronic: https://www.medtronic.com/covidien/en‐ us/products/hernia‐repair/fixation‐ products.html (accessed Feb 22,2022) Bard: https://www.bd.com/en‐ us/offerings/capabilities/hernia‐repair‐ and‐fixation/fixation‐system (accessed Feb 22,2022) Via Surgical: https://www.viasurgical.com/Science/ accessed Feb 22,2022).
7. Ethicon, ORN‐50‐3090 Tack Comparison CAD Surface Area Drawing, April 2010.
8. ETHICON, SecureStrap Design Reliability Memo., May 3, 2010. DOCUMENT: 25/2‐ 65674 TRIM database.
9. ETHICON, Completion Report Developmental Study for Ethicon Securestrap Fixation Device, Engineering Build Groups 5&6 ‐ Design Reliability, 4/22/2010, Document: DVERCR0002325, ADAPTIV.
10. Doerhoff C, Chudy M, Gauld J et al. Preliminary Outcomes using an absorbable fixation device for mesh fixation. AHS 2013 SECURESTRAP (poster).
11. Redan J, et al. 12-month patient reported outcomes following hernia repair with an absorbable ixation device. International Hernia Mesh Registry. 2016.
Clinical and technical support is available 24/7 at 1-877-ETHICON (384-4266)
For complete indications, contraindications, warnings, precautions, and adverse reactions, please reference full package insert.
The third-party trademarks used herein are trademarks of their respective owners.
US_SRG_HERN_219074.1
.png?width=3840&quality=90&format=webp)