ECHELON CONTOUR™ Curved Cutter

Stapling deep within the pelvis creates challenges with achieving good staple formation, increasing the risk of leaks. The ECHELON CONTOUR™ Curved Cutter is engineered to address the difficulties of access and varying tissue conditions. It's designed to reduce leak risks1-3A through gentle tissue handling and a strong staple line, without compromising healing.3-5B

About this device

ECHELON CONTOUR™ Curved Cutter is designed for improved usability and performance when cutting and stapling in colorectal procedures.6
Two different staple reloads are available for standard and thick tissue, and the device may be reloaded and fired multiple times when needed.7 

Specialties

Colorectal

Procedures

Low Anterior Resection, Sigmoidectomy

Features & benefits

Less tissue trauma

Gripping Surface Technology (GST)—a proprietary ridged surface on the staple reload—precisely compresses tissue only where needed for 31% reduced compressive forces on tissue and 37% less tissue trauma compared to traditional flat deck staplers.3-5B

Reduced potential leak pathways

With a gentler curved design, 3D Stapling Technology minimized high stress points throughout the staple line and evenly distributed compression throughout the staple line to reduce potential leak pathways.1C

Deep pelvic access

Designed for increased visibility and optimal use in the narrower male pelvis, the unique curved head design of the ECHELON CONTOUR™ Curved Cutter gives low pelvic access and enhanced visibility of anatomic structures.8

Learn how to use this device

Supporting documentation

PDF

ECHELON CONTOUR™ Curved Cutter optimal device performance guide

PDF

ECHELON CONTOUR™ Curved Cutter fact sheet
Select all (2)

Related products

 ECHELON CIRCULAR™ Powered Stapler

ECHELON CIRCULAR™ Powered Stapler

Leaks during surgery can lead to serious complications, especially in challenging cases. The ECHELON CIRCULAR™ Powered Stapler significantly reduced leaks at the staple line and produced greater perfusion compared to the Medtronic EEA™ Circular Stapler with Tri-Staple™ Technology.1,2A The device combines two breakthrough innovations—3D Stapling and Gripping Surface Technologies—on one consistent and reliable powered platform.

ECHELON LINEAR™ Cutter

Leaks can have a devastating impact for patients and hospitals. Compounding this challenge, increasing patient complexity in some open procedures further elevates the risk of leaks. The ECHELON LINEAR™ Cutter provided 47% fewer staple line leaks compared to the PROXIMATE™ Linear Cutter and GIA™ Stapler with Tri-Staple™ Technology.1A

References

A. Risk factors for leaks include the following: tissue trauma and a staple line with uneven compression. Benchtop testing on porcine colon comparing mean mucosal capture of 46.3% (n=30) for ECHELON CONTOUR™ to 74.46% (n=30) for CONTOUR™ Curved Cutter Stapler (p<0.05). Finite element‐based computational simulations (FEA) on simulated porcine tissue measuring tissue compression after approximation and staple formation, comparing average standard deviation of 5.481 for 2D staples to 5.109 for 3D staples (n=37, p<0.05).

B. Benchtop testing in porcine colon comparing mean compression load of 22.35 lbf (n=32) for ECHELON CONTOUR™ to 32.56 lbf (n=30) for CONTOUR™ Curved Cutter Stapler (p<0.05) and comparing mean mucosal damage of 46.3% (n=30) for ECHELON CONTOUR™ to 74.46% (n=30) for Contour (p<0.05).

C. Finite element-based computational simulations (FEA) on simulated porcine tissue measuring tissue compression after approximation and staple formation, comparing average standard deviation of 5.481 for 2D staples to 5.109 for 3D staples (n=37, p<0.05).

  1. Ethicon, Silhouette Tissue Compression Simulation (FEA) [Claims]. 6.30.2020. Windchill Document #PRC093448
  2. Ethicon, Silhouette GST Analysis of Design [Claims – EU]. 10.27.2020. Windchill Document #500561007
  3. Ethicon, Silhouette Shaft Compression Force Claims Testing. 01.16.2020. Windchill Document #PRC092073
  4. Ethicon, Silhouette Tissue Trauma Claims Testing. 1.26.2021. Windchill Document #PRC091995
  5. Ethicon, Evaluation of the Tissue Healing Response Following Use of the Silhouette Device for Colonic Anastomoses in Swine - 7 and 21 Days. 03.06.2020. Windchill Document#PSP007621
  6. Ethicon, ECHELON CONTOUR™ Curved Cutter Design Claims Memorandum. 08.18.2020. Windchill Document #SCN075253
  7. ECHELON CONTOUR™ Curved Cutter Instructions for Use. Ethicon, Inc.
  8. Ethicon, Silhouette Pelvic Access Study [Claims]. 03.03.2020. Windchill Document #PRC093434


For complete indications, contraindications, warnings, precautions, and adverse reactions, please reference full package insert. 


The third-party trademarks used herein are trademarks of their respective owners. 

US_SRG_STAP_117704.1