Intended for healthcare professionals

EP diagnostic catheters

Our advanced diagnostic catheters offer high resolution mapping when additional diagnostic insights are desired.


With real-time 3D visualization enabled by the CARTO™ 3 System and the integrated solutions designed to complement it, you have the insights needed for confidence in your outcomes.

Studies

A physician looking at OCTARAY™ Mapping Catheter.

An early multicenter experience of the novel high-density star-shaped mapping catheter in complex arrhythmias1

Sarkozy, A, et al. (2022); J Interven Card Electrophysiology

OPTRELL™ Mapping Catheter

Substrate and arrhythmia characterization using the multi-electrode OPTRELL™ Mapping Catheter for ventricular arrhythmia ablation2

Tan, J. L., et al. (2024) Journal of Interventional Cardiac Electrophysiology

Clinical specialists in the control room looking into the procedure room during a case.

Multipolar Electrograms: A new configuration that increases the measurement accuracy of intracardiac signals.3

Anter, E., et al. (2024); JACC: Clinical Electrophysiology,10(7), Part 2, 1521-1533

Two physicians looking at a CARTO™ map.
Two physicians looking at a CARTO™ map.

Part of an integrated system

Our product innovations through integration are designed to unlock the full potential of your practice.

This integration goes beyond the simple coexistence of different instruments – it is a conscious effort to create a synergistic system that enhances overall performance and outcomes.

Learn more about our CARTO-integrated portfolio
OCTARAY™ Mapping Catheter with TRUEref™ Technology
OCTARAY™ Mapping Catheter with TRUEref™ Technology
Advanced diagnostics

True clarity, speed, integration

OCTARAY™ Mapping Catheter with TRUEref™ Technology

The OCTARAY™ Mapping Catheter with TRUEref™ Technology is designed to improve signal quality, enhance mapping speed, and unleash the full potential of the CARTO™ 3 System.**,i,4,5

> 50%

Decrease in mapping time4a

In a pre-clinical study, mapping time was 56% shorter with the OCTARAY™ Mapping Catheter than with the PENTARAY™ Mapping Catheter.

2x

EGMs per map5b

In a pre-clinical study, the number of EGMs per map collected with the OCTARAY™ Mapping Catheter was 2 times higher than the PENTARAY™ Mapping Catheter

Complex made clear
Complex made clear
Advanced diagnostics

Complex made clear7

OPTRELL™ Mapping Catheter with Multipolar Technology

To aid in the most complex cases, the OPTRELL™ Mapping Catheter with Multipolar Technology’s intuitive design and fixed electrode array work with the CARTO™ 3 System to deliver intelligent insights and high-resolution directional mapping.8,9

Intelligent Insights: OPTRELL™ Mapping Catheter and CARTO™ 3 System combine to assist with detailed understanding of complex circuits and mechanisms.7

Optimal maneuverability: OPTRELL™ Mapping Catheter was rated highly for its maneuverability and its ability to deploy in the left and right atrium.10

Improvement in signal: OPTRELL™ Mapping Catheter with Multipolar Technology significantly reduces far field [FF] potentials, improving identification of local potential in the Unipolar signals.d,e,11

DECANAV™ Mapping Catheter
DECANAV™ Mapping Catheter
Core diagnostics

Multi-electrode mapping

DECANAV™ Mapping Catheter

The DECANAV™ Mapping Catheter is a high-performance diagnostic catheter designed for multi-electrode mapping of the intricate left ventricle and the right atrium. Its familiar shape is slim-fitting and handles easily, so you can FAM and MEM* with confidence.12

Multi-electode mapping of intricate heart structures: Extends access throughout confined spaces and helps facilitate high-resolution outflow tract and subtrate mapping. Tip electrode supports mapping of difficult-to-reach areas.

High resolution mapping: When used with our CARTO™ 3 MEM Module it allows you to sample multiple points of cardiac mapping data simultaneously. MEM technology also provides high resolution maps with fewer maneuvers required to reposition catheters.

Dr. Paul Haas MD, FACC, Electrophysiologist
Multipolar mapping...is by far the most efficient way to characterize the nature of the patient’s ventricle or the tissue you’re interested in.

Dr. Paul Haas

MD, FACC, Electrophysiologist

Supporting with excellence

Supporting documentation

PDF

The Value of OPTRELL™ Mapping Catheter
Select all (1)

Browse products

References

DO NOT use PENTARAY™ NAV ECO High Density Mapping Catheters, OCTARAY™ or OPTRELL™ Mapping Catheters with TRUEref™ Technology in patients with prosthetic valves.


The THERMOCOOL SMARTTOUCH™ SF Catheter is indicated for the treatment of drug refractory recurrent symptomatic paroxysmal atrial fibrillation (AF) and for drug refractory recurrent symptomatic persistent AF (continuous AF > 7 days but < 1 year), refractory or intolerant to at least 1 Class I or III AAD, when used with the CARTO™ 3 System.


* Compared to the PENTARAY® NAV eco High Density Mapping Catheter. Based on a single-center, preclinical study (n=8) and benchtop study.

**Pre-clinical test data are not necessarily indicative of clinical performance

i. Study was a comparison of OCTARAY™ Catheter 2-2-2 vs PENTARAY® Catheter 2-6-2. Based on bench testing.

a Pre-clinical results with swine left ventricles: normal (n=4), with infarction (n=8). Pre-clinical test data are not necessarily indicative of clinical performance. 

b. Based on OCTARAY™ Mapping Catheter with TRUEref™ Technology results from a single arm (n=31) pre-clinical trial. Pre-clinical test data are not necessarily indicative of clinical performance.

c. Compared to PENTARAY™ NAV ECO High Density Mapping Catheter.

d. Compared to previous version of CARTO™ 3 System software.

e. The preclinical validation was conducted using retrospective analysis of 4 atrial flutter maps with or without pacing (2xRA and 2xLA) and 12 ventricular maps (3xVTs and 9x ischemic OPTRELL™ (part number D-1409) Catheter on CARTO™ 3 System.


  1. Sarkozy A, Vijgen J, De Potter T, Schilling R, Markides V. An early multicenter experience of the novel high-density star-shaped mapping catheter in complex arrhythmias. J Interv Card Electrophysiol. 2022 Jun;64(1):223-232. doi: 10.1007/s10840-022-01176-2. Epub 2022 Mar 26. PMID: 35347507.
  2. Tan JL, Guandalini GS, Hyman MC, Arkles J, Santangeli P, Schaller RD, Garcia F, Supple G, Frankel DS, Nazarian S, Lin D, Callans D, Marchlinski FE, Markman TM. Substrate and arrhythmia characterization using the multi-electrode Optrell mapping catheter for ventricular arrhythmia ablation-a single-center experience. J Interv Card Electrophysiol. 2024 Apr;67(3):559-569. doi: 10.1007/s10840-023-01618-5. Epub 2023 Aug 18. PMID: 37592198.
  3. Anter E, Brem O, Greenbaum L, Bubar ZP, Younis A, Yavin H, Yarnitsky J, Barkagan M. Multipolar Electrograms: A New Configuration That Increases the Measurement Accuracy of Intracardiac Signals. JACC Clin Electrophysiol. 2024 Jul;10(7 Pt 2):1521-1533. doi: 10.1016/j.jacep.2024.04.009. Epub 2024 May 16. PMID: 38752962.
  4. Barkagan M, Sroubek J, Shapira-Daniels A, et al. (2020) A novel multi-electrode catheter for high-density ventricular mapping: electrogram characterization and utility for scar mapping. Europace (0): 1-10.
  5. Sroubek J, Rottmann M, Barkagan M, Leshem E, Shapira-Daniels A et al. (2019) A novel octaray multielectrode catheter for high-resolution atrial mapping: Electrogram characterization and utility for mapping ablation gaps. J Cardiovasc Electrophysiol 30 (5): 749-757.
  6. Sarkozy AV, Johan; De Potter, Tom; Schilling, Richard; Markides, Vias (2020) Higher Density Mapping Efficiencies and Ease of Maneuverability from the OCTARAY First in Man Study. European Heart Rhythm Association 2020. Vienna, Austria. March 29th-31st, 2020. Pending formal publication.
  7. Yavin H et al. Propagation Vectors Facilitate Differentiation Between Conduction Block, Slow Conduction, and Wavefront Collision. Circ Arrhythm Electrophysiol. 2021 Aug;14(8):e010081.
  8. OPTRELL™ Mapping Catheter IFU M-5276-1121A
  9. CARTO 3 System Instructions for Use, Software Version 8.1. UG-5400-008H (00A)
  10. Vijgen J, Račkauskas G, Dilling-Boer D, Sarkozy A, Ciconte G, Vicedomini GG, Pappone C. Safety and feasibility of a novel multielectrode array catheter in mapping atrial and ventricular arrhythmias with high density: results from the multicenter OPTIMUM study. J Interv Card Electrophysiol. 2023 Oct;66(7):1563-1565. doi: 10.1007/s10840-023-01568-y. Epub 2023 May 25. PMID: 37227536; PMCID: PMC10547614.
  11. REP15094 - CARTO 3 V8 Clinical Validation for MULTIPOLAR Clinical Validation Report.
  12. Sousa PA, António N, Barra S, Elvas L, Gonçalves L. Pattern matching filter and multielectrode mapping catheter — a new approach for complex premature ventricular contraction ablation. Rev Port Cardiol. 2021;40(6):423-431. doi:10.1016/j.repc.2020.08.009.


US_ELP_DIAG_407268