Features & Benefits

Less compressive forces on tissue2†
Gripping Surface Technology (GST), a proprietary ridged surface, precisely compresses tissue where needed.3

Designed to evenly distribute compression throughout the staple line1*
With a gentle curved design, 3D Stapling Technology is designed
- to minimize high stress points throughout the staple line1*
- to evenly distribute compression throughout the staple line1*
- to limit potential leak pathways1*

Fewer Leaks at the Staple Line4‡
The ECHELON CIRCULAR Powered Stapler combined with crossing staple lines from the ECHELON CONTOUR Curved Cutter Stapler significantly reduced leaks at the staple line in colon tissue compared to the Medtronic DST Series EEA stapler combined with crossing staple lines from the Endo GIA Radial Reload with Tri-Staple Technology. 4‡

Less Tissue Slippage5§
With its parallel closure and tissue retaining pin, Echelon Contour Curved Cutter produced 9.1mm less tissue slippage during firing compared to Medtronic Endo GIA Radial Reload with Tri‐Staple Technology.5§

Designed to be Reloaded
The ECHELON CONTOUR Curved Cutter Stapler’s reloadable architecture with staple overlap to the retention pin allows surgeons to create a continuous, extended staple line over multiple firings. The knife extends to the tissue retaining pin and the staple line extends beyond the pin. Helps avoid overloading tissue in the jaws of the device.6

Same deep pelvic access you depend on from the original CONTOUR Curved Cutter7¶
The ECHELON CONTOUR Curved Cutter Stapler has a 21% smaller head width than Endo GIA™ Radial Reload with Tri-Staple™ Technology to enable deep pelvic access.8β The small head design allows placement of a 40mm cut line in the width of a 30mm space.9
Resources
Resources
References
* Finite element-based computational simulations (FEA) on simulated porcine tissue measuring tissue compression after approximation and staple formation, comparing average standard deviation of 5.481 for 2D staples to 5.109 for 3D staples (n=37, p<0.05).
† Benchtop testing in porcine colon comparing mean compression load of 22.35 lbf (n=32) for ECHELON CONTOUR to 32.56 lbf (n=30) for CONTOUR (p<0.05)
‡ Benchtop testing in porcine colon compared the rate of staple line leak failure at ≤30mmHg, compared Ethicon CDH29P/GCS40B to Medtronic SIGRADMT/EGIAUSTND/EEA2835, n=31 ea, p<0.05
§ Benchtop testing measuring change in cutline length, comparing means of 15.3mm for Medtronic Endo GIA™ Radial Reload with Tri-Staple™ Technology to 6.20mm for Ethicon Echelon Contour (n=15, p<0.05).
¶ Unique curved head design gives low pelvic access.
β ECHELON CONTOUR™ Curved Cutter Stapler, head width, 2.53in compared to Medtronic Endo GIA™ Radial Reload with Tri-Staple™ Technology, head width, 3.22in.
1. Ethicon, 500561940A.7 Silhouette Tissue Compression Simulation [Claims – EU], Oct 2020 Ethicon, 500632160A Design Intent for Echelon Contour Curved Cutter, Jan 2021, Data on file (170554-210315 EMEA)
2. Ethicon, 500632160A Design Intent for Echelon Contour Curved Cutter, Jan 2021, Data on file Ethicon, PRC092073A Silhouette Shaft Compression Force Claims Testing, Jan 2016, Data on file (166727-210208 EMEA)
3. Ethicon, 500632160A Design Intent for Echelon Contour Curved Cutter, Jan 2021, Data on file (166725-210208 EMEA)
4. Ethicon, PRC094924A CDH29P and GCS40B Leak Claims Testing: Ethicon Portfolio Compared to Medtronic Portfolio, May 2020, Data on file (162308-201209 EMEA)
5.Ethicon, PRC093137A Evaluation of Tissue Movement During Stapler Firing: Silhouette vs. Endo GIA Radial Reload Stapling Devices, Jan 2020, Data on file (162310-201209 EMEA)
6. Ethicon, SCN075253B Echelon CONTOUR Curved Cutter Design Claims Memorandum Approvals, Sep 2020, Data on file (162311-201209 EMEA)
7. Ethicon, PRC093434A Silhouette Pelvic Access [Claims], March 2020, Data on file (162307-201209 EMEA)
8. Ethicon, PRC0954405A Silhouette vs. Competitor Head Width [Claims], March 2020, Data on file Ethicon, PRC093434A Silhouette Pelvic Access [Claims], March 2020, Data on file (162306-201209 EMEA)
9. Ethicon, SCN075253C Echelon CONTOUR Curved Cutter Design Claims Memorandum Approvals, August 2020, Data on file (164642-210115 EMEA)
180125-210616 EMEA/UK
© Johnson & Johnson Medical Limited 2021. All Rights Reserved.
Please refer always to the Instructions for Use / Package Insert that come with the device for the most current and complete instructions.