This webpage content is intended for Health Care Professionals (HCP’s) only.
Intended for Healthcare Professionals
Intended for HCPs
2.4 mm Variable Angle LCP™ Volar Extra-Articular Distal Radius System
Plates are available left or right with 3-hole or 5-hole shaft length
The anatomically pre-contoured plates featuring variable angle locking are indicated for fixation of intra- and extra-articular fractures and osteotomies of the distal radius.
ACRION™ Saw Blades
ACRION™ Saw Blades are designed for joint reconstruction surgeries. They are supplied exclusively in sterile packaging for single use.
Designed to prevent oxidation to potentially maintain mechanical integrity and oxidative stability.
Designed for better patient outcomes, the ATTUNE™ Cementless Fixed Bearing Knee with AFFIXIUM™ 3D Printed Technology provides better kinematics1-3, enhanced initial stability4, and advanced biologic fixation5 for total knee arthroplasty.
Used together, the ATTUNE™ Knee and Patient-Specific Alignment Techniques are designed to preserve the soft tissue envelope and reduce the requirement for soft tissue releases, helping to restore stable knee motion and improve patient satisfaction after total knee arthroplasty (TKA).
The ATTUNE™ Revision Knee System provides a modern revision knee system scientifically designed for STABILITY IN MOTION™ that more closely matches the kinematics of the natural knee to allow for functional knee restoration and improve patient satisfaction.1,2 The system is designed to simplify the complex, with joint line restoration and flexion gap solutions, streamlined patient-specific workflows, intentional system continuity, and the power of KINCISE™ technology.
The BPL II platform has been developed for joint reconstruction surgery yet is flexible to address orthopaedic surgical needs.
BI-MENTUM™ Dual Mobility System
A monoblock dual mobility hip system.
BIOCRYL RAPIDE™ is a biocomposite material. A proprietary Micro-Particle Dispersion (MPD) manufacturing process provides a homogenous dispersion of the composite materials*, while ensuring β-TCP is in close apposition with the surrounding bone tissues. * Non-homogeneous composites may result in a material with compromised or variable strength properties due to stress risers within the material.
The bone reduction forceps with a radiolucent J-shaped soft tissue attachment is intended for reduction of distal radius fractures following a volar approach. It aids in fracture reposition and allows straight-forward plate fixation.
C-STEM AMT is a triple tapered, polished cemented stem indicated for both Primary and Revision (In-Cement and Long-Stem revision) cases. C-STEM AMT has a comprehensive size range available in both standard and high offset.
Cannulated Compression Headless Screw
Availability of sterile packaging variant is dependent on the market.
The key feature of the CONCORDE Bullet Interbody Cage is the bulleted nose for ease of insertion into the interbody space. Available in carbon fiber reinforced polymer (CFRP), titanium, and titanium integrated material (PROTI 360°™), CONCORDE Bullet offers optimized area for bone graft and tantalum markers (CFRP option) also allow you to visualize the position of the cage in situ. CONCORDE Bullet is designed for surgeons who prefer a straight, oblique placement of the implant and is intended to be used with supplementary posterior instrumentation.
The CONCORDE® Clear MIS Discectomy Device is single-use, sterile packed instrument that enables disc clearing and endplate preparation through a minimally invasive approach, using a suction-curette mechanism.
CONDUIT™ Interbody Platform
The CONDUIT™ Interbody Platform is a comprehensive portfolio of 3D-printed porous titanium interbody devices intended to stabilize the spinal segment, restore intervertebral height and to facilitate interbody fusion in the cervical (C2-T1) and lumbar spine (L2-S1) and are designed to mimic the published properties of bone.1
The COR™ Precision Targeting System is a single patient use pre-sterile Osteochondral Autograft Transfer System featuring “No Impact Transfer” and “Low Impact Delivery” for protection of chondrocyte viability.
One system for mandibular and cranial use in pediatric and adult patients1,2.Flexible solutions to meet the needs of each patient. One system. Four Indications. 1000+ configurations.1-3
DELTA XTEND™ Reverse Shoulder System
The DELTA XTEND™ Reverse Shoulder System is a total semi-constrained shoulder arthroplasty. It reverses the normal relationship between the scapular and humeral components, moving the scapulo-humeral joint center of rotation medially and inferiorly. It is intended for use in total reverse or hemi-shoulder replacement procedures.
LCP® Dynamic Hip Screw (DHS) incl. DHS Blade and Locking Trochanter Stabilization Plate (LTSP) is designed for the treatment of proximal femoral fractures.
You are about to leave jnjmedtech.com. By clicking to continue, you will be taken to a web site governed by their own Legal and Privacy Policies.