Instructions for Use

RFN-Advanced™ Brochure
Features & Benefits

Multi-planer, decending oblique screw pattern
- Two descending oblique screws target denser posterior condyles.

Angular Stability
- Locking Polymer is built into the nail for angular stability in all distal locking screws without additional steps, end caps, or special instruments.1-3
- Designed to avoid the challenges associated with cross-threading and cold-welding.1-3

Distal Scew Density
- 3.5mm Variable Angle Locking Screws designed to fit around the nail and interlocking screws.4

Locking Attachment Washer (LAW)
- The addition of the Locking Attachment Washer increases the fixation strength by 44% compared to nailing alone.5

Condylar Nut and Washer
- Condylar Nuts increase surface contact with cortical bone to improve stability compared to standard screws.6

Periprosthetic Nail with 10° Distal Bend
- Periprosthetic Nail is designed to reduce the likelihood of an extension deformity that
can result from a posterior entry point in TKA patients.7

Intuitive, Connected Instrumentation
- Shared Base Instruments provide consistency to support reduction in storage, duplication and staff learning.8
- Secure retention instrumentation - Solid “screw to screwdriver” connection. Same drivers used for both screws, available in manual and power
- Quick connect latch – efficient assembly/disassembly
- Twist and lock – protection sleeves secured in aiming arm
- Simplified guided alignment – aiming arm supports LAW and Nut technique

Designed to help maintain alignment of the distal fragment, the Locking Polymer reduces screw toggle by 80% and holds the screw in position relative to the nail, increasing pull out strength up to 128%, compared to a nail without Locking Polymer.2,3,6

Nails designed with flats medially and laterally for a max width of 11.2mm to fit through narrow open box prostheses.7
Resources

Request Sales Rep
If you wish to learn more about this product, submit a request and a representative of DePuy Synthes will be in touch shortly.

Request Brochure
If you require a printed or digital brochure or surgical technique for this product, submit your request and we will send it to you.

Other Requests
Have a different kind of query? Simply fill out the details of your request and we will get back to you as soon as possible.
Supporting Documentation
References
*Bench testing may not be indicative of clinical performance.
Refer to references 1-6 for stability claims.
- DePuy Synthes RFNA Locking Polymer Rationale. 09/30/2020. Windchill Document #0000302368
- DePuy Synthes RFNA Nail Inlay Axial Pullout Design Verification Report. 08/20/2020. Windchill Document #0000293479
- DePuy Synthes RFNA Poly Inlay Angular Stability Test Report. 09/29/2020. Windchill Document #000306551
- DePuy Synthes RFN-Advanced System Locking Attachment Washer Rationale. 09/30/2020. Windchill Document #0000302371
- DePuy Synthes, RFNA Nail/LAW Static Construct Design Verification Report. 4/28/2020. Windchill #0000293480*
- DePuy Synthes test result summary for Secure Retaining Screws. 08/17/2020. Windchill Document #0000295306*
- DePuy Synthes RFN-Advanced System Nail TKA Fit Rationale. 09/30/2020. Windchill Document #0000302370
- DePuy Synthes Advanced Nail System Instrument Summary. 09/30/2020. Windchill Document #0000302373
168679-210416
© DePuy Synthes 2023. All rights reserved.
This site is published by the DePuy Synthes Companies, which are solely responsible for its content. This site is for visitors from Europe, Middle East and Africa.
The third party trademarks used herein are trademarks of their respective owners.
Product(s) may not be commercially available in all markets. This content may not be used externally in those markets where regulatory approval has not been granted for all the products referenced.
Please refer to the instructions for use for a complete list of indications, contraindications, warnings, and precautions.